Please cite as: CSH Protocols; 2006; doi:10.1101/pdb.prot4417
| Protocol |
This protocol was adapted from "Production of Chimeras," Chapter 11, in Manipulating the Mouse Embryo, 3rd edition, by Andras Nagy, Marina Gertsenstein, Kristina Vintersten, and Richard Behringer. Cold Spring Harbor Laboratory Press, Cold Spring Harbor, NY, USA, 2003.
| The first 15% of the full text of this article appears below. |
INTRODUCTION
Injection needles require sharp tips that allow the blastocyst to be penetrated easily. This protocol describes a method of creating sharp injection needle tips.
MATERIALS
Equipment
Pulled injection needles (see Making Injection Pipettes)
Scalpel, disposable
Silicon tubing, very thick (external diameter 15-20 mm)
Stereo
METHOD
Related Protocol