Cite as: Cold Spring Harb. Protoc.; 2006; doi:10.1101/pdb.prot4530

This Protocol
Right arrow Full Text
Right arrow Update/discuss this protocolDiscussion icon
Right arrow Alert me when this protocol is cited
Right arrow Alert me when comments are published
Right arrow Alert me if a correction is posted
Services
Right arrow Similar protocols in this database
Right arrow Alert me to new releases of protocols
Right arrow Save to Personal Folders
Right arrow Download to citation manager
Right arrow Printer-friendly versionPrinter-friendly version
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Harlow, E.
Right arrow Articles by Lane, D.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Harlow, E.
Right arrow Articles by Lane, D.
Related Collections
Right arrow Antibodies, general
Right arrow Imaging/Microscopy, general
Right arrow Immunostaining, general
Right arrow Immunostaining Tissues
Right arrowRelated Protocols
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Legend icon

protocolProtocol

Unmasking Hidden Epitopes Using the Pressure Cooker

Ed Harlow and David Lane

This protocol was adapted from "Staining Tissues," Chapter 6, in Using Antibodies by Ed Harlow and David Lane. Cold Spring Harbor Laboratory Press, Cold Spring Harbor, NY, USA, 1999.


INTRODUCTION

Several methods have been developed to "retrieve" antigens that have been masked by fixation. The principle behind the pressure cooker method described here is to use extended periods of heat to break some of the subcellular structures that block antibody access. This approach is appropriate for handling specimens on glass slides. The major advantages of the pressure cooker method are the ability to handle a large number of slides simultaneously, the convenience of using metal racks, and the avoidance of any hot spots that are found in the microwave. Be aware that any of the antigen retrieval methods should be avoided wherever possible, because they may introduce artifactual false-positive staining. Methods for antigen retrieval are specific for each antibody/antigen combination. No attempts to establish quantitative data following these methods should be considered.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

Related Protocols

Preparing Paraffin Tissue Sections for Immunostaining
Ed Harlow and David Lane
CSH Protocols 2006: 4329. [Extract] [Full Text]

Binding Antibodies to Tissue Sections
Ed Harlow and David Lane
CSH Protocols 2006: 4331. [Extract] [Full Text]

Unmasking Hidden Epitopes with Proteases
Ed Harlow and David Lane
CSH Protocols 2006: 4528. [Abstract] [Full Text]

Unmasking Hidden Epitopes Using the Microwave Oven
Ed Harlow and David Lane
CSH Protocols 2006: 4529. [Abstract] [Full Text]