Please cite as: CSH Protocols; 2006; doi:10.1101/pdb.prot4663

This Protocol
Right arrow Full Text
Right arrow Update/discuss this protocolDiscussion icon
Right arrow Alert me when this protocol is cited
Right arrow Alert me when comments are published
Right arrow Alert me if a correction is posted
Services
Right arrow Similar protocols in this database
Right arrow Alert me to new releases of protocols
Right arrow Save to Personal Folders
Right arrow Download to citation manager
Right arrow Printer-friendly versionPrinter-friendly version
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Niessen, S.
Right arrow Articles by Yates, J. R.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Niessen, S.
Right arrow Articles by Yates, J. R., III
Related Collections
Right arrow Proteins and Proteomics, general
Right arrow Characterization of Protein Complexes
Right arrow Mass Spectrometry
Right arrow Chromatography, general
Right arrow Liquid Chromatography
Right arrow Protein: Protein Interactions, general
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Legend icon

protocolProtocol

HPLC Separation of Digested Proteins and Preparation for Matrix-Assisted Laser Desorption/Ionization Analysis

Sherry Niessen, Ian Mcleod, and John R. Yates, III

This protocol was adapted from "Identification of Novel Protein Complexes and Protein-Protein Interactions by Mass Spectrometry," Chapter 18, in Protein-Protein Interactions , 2nd ed. (eds. Golemis and Adams). Cold Spring Harbor Laboratory Press, Cold Spring Harbor, NY, USA, 2005.


INTRODUCTION

Two types of columns are commonly used for the separation of peptides by HPLC. A single-phase column contains the reverse-phase resin C18, which interacts with the hydrophobic moieties of the peptides. Peptides resulting from digestion of simple mixtures of proteins are loaded onto the single-phase column and eluted into the mass analyzer using an increasing gradient of an organic solvent. Peptides resulting from the digestion of more complex mixtures of proteins are resolved using a biphasic column. This column integrates both a strong cation exchange SCX resin, which interacts with peptides as a result of their positive charge, and a reverse-phase C18 resin, packed in tandem. Peptides initially interact with the SCX resin and are eluted into the C18 resin by ammonium acetate that competes for the peptide-binding sites. Peptides are then eluted from the C18 resin into the mass analyzer. This process is repeated using increasing concentrations of ammonium acetate to differentially elute peptides in a stepwise fashion. The biphasic column also uses an additional C18 reverse-phase resin linked through an Inline MicroFilter Assembly (Upchurch) to desalt the peptides prior to loading onto the SCX. The desalting and biphasic columns are combined to give an integrated desalting/biphasic column.